DYNAMIC GARMENT CABINET
The application of Garment Cabinet is for storing the sterile aprons. The unit is used to avoid the dust contaminations as well as the bacterial growth. Unit is used in
pharmaceuticals, Bio-tech, Food, Electronic Industries. The work area is continuously supplied with positive pressure HEPA filtered recirculated air flow.
Description
Description – DYNAMIC GARMENT CABINET (MOC SS 304, 316,316L )
HEPA Filter | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% for 0.3 micron |
---|---|
Pre-filter | Pre-filters are made from Non-woven synthetic with HDPE mesh; conforms to EU-06 Grade, with an efficiency rating better than 95% down to 5 micron |
Fresh Air Filter | Fresh Air filters are made from Non-Woven Synthetic with HOPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10 micron |
Motor blower assembly | Motor blower designed of statically” and dynamically balanced for supply of sufficient capacity and static pressure to take care of air flow requirement for entire life of HEPA Filter |
Pressure Gauge | Magnehelic Gauge (0-25 mm:1 Nos.)to monitor pressure drop across HEPA Filter |
Door | SS 304 doors with double walled flush Toughened glass view panels with SS handles. |
Interlocking | Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens and LED Light on. |
Shelves | SS 304 hanging arrangement (or removable type shelves |
Temperature Control | Heater with thermostat for control of temperature in cabinet |
On/Off Switches | Keypad ON/OFF Switches for motor & UV Light & Led Light |
Switch socket | 6/15 Amp Single phase switch socket use for external equipment |
DOP Port | DOP test port at up stream of HEPA filter Integrity test. (With PAO Solution) |
Vibration Level | Minimum |
Electric Supply | 230V AC 1-Ø 50 HZ/415V AC 3-Ø 50 HZ |
Noise Level | Less than 67 dB on Scale ‘A’ when Ambient is not greater than 55 dB on Scale ‘A’ |
1) UV. Light with Hour Meter
2) Electro Magnetic / Mechanical Interlocking
3) Audio Visual Alarm indicating condition of HEPA filters.
4) Clean down timer with operation hold indicator
5) VFD based control systems.
6) Photohelic guage/ Digital pressure gauge to monitor of pressure drop across filter.
7) Sodium vapor lamps
8) Flame proof fitting